Threaded ends | DN32 to DN80 |
Flanged ends | DN40 to DN300 |
Threaded type | BSP according to ISO 228-1 |
Flanged type | EN 1092-2 PN16 and AS4087 (AS2129 Table E) |
Maximum working pressure | 16 bars |
Operating temperatures | 10°C ~ 80°C |
Seating | according to category A standard ISO 5208 |
Minimum backpressure for tightness | 0.3 bar to 0.5 bar |
Face to Face dimensions for flanged type | according to EN-558-1 serie 48 (DIN3202 F6) |
Applications
Pumping stations for clean, sewage water and loaded or viscous fluids.
Technical performance
Dimensions in mm
Size | L | EN1092-2 PN10 | b | H | Weight (kg) | |||
---|---|---|---|---|---|---|---|---|
D | D1 | D2 | n-d | |||||
DN40 | 180 | 150 | 98 | 78 | 4-14 | 19 | 90 | 6.0 |
DN50 | 200 | 165 | 114 | 90 | 4-18 | 19 | 100 | 6.5 |
DN65 | 240 | 185 | 127 | 103 | 4-18 | 19 | 125 | 11.0 |
DN80 | 260 | 200 | 146 | 122 | 8-18 | 19 | 136 | 14.4 |
DN100 | 300 | 220 | 178 | 154 | 8-18 | 19 | 185 | 20.0 |
DN125 | 350 | 250 | 210 | 186 | 8-18 | 19 | 196 | 30.4 |
DN150 | 400 | 285 | 235 | 207 | 8-22 | 19 | 265 | 42.3 |
DN200 | 500 | 340 | 292 | 264 | 8-22 | 20 | 340 | 73.5 |
DN250 | 600 | 405 | 356 | 328 | 12-22 | 22 | 420 | 128.0 |
DN300 | 700 | 460 | 406 | 374 | 12-26 | 24.5 | 480 | 180.0 |
DN350 | 800 | 520 | 460 | 429 | 16-23 | 26.5 | 615 | |
DN400 | 900 | 580 | 515 | 480 | 16-28 | 28 | 680 | |
DN450 | 1000 | 640 | 565 | 548 | 20-28 | 30 | 791 | |
DN500 | 1150 | 715 | 620 | 609 | 20-28 | 31.5 | 866 | |
DN600 | 1350 | 840 | 725 | 720 | 20-31 | 36 | 1110 |